EXPORT CITATION

Chapter-12 19 Gauge: The Port of Entry to Biaxial Lens Surgery

BOOK TITLE: Biaxial Lens Surgery

Author
1. Arteaga Arturo Perez
2. Weinstock Robert J
3. Bovet Jerome
ISBN
9788184482218
DOI
10.5005/jp/books/10793_12
Edition
1/e
Publishing Year
2008
Pages
20
Author Affiliations
1. Centro Oftalmologico Tlalnepantla, Dr Perez - Arteaga Vallarta No. 42, Tlalnepantla, Centro, Estado de Mexico, Mexico, Centro Oftalmologico Tlalnepantla, Dr. Perez-Arteaga Vallarta No. 42, Tlalnepantla, Centro, Estado de Mexico, 54000, Mexico, Centro Oftalmologico Tlalnepantla, Dr Perez-Arteaga Vallarta No. 42, Tlalnepantla, Centro Estado de, Mexico, Centro Oftalmologico Tlalnepantla, Dr. Perez – Arteaga Vallarta No. 42, Tlalnepantla, Centro, Estado de Mexico, 54000, Mexico, Centro Oftalmológico, Tlalnepantla, Vallarta # 42, Tlalnepantla, México, Centro Oftalmologico Tlalnepantla, Dr. Perez - Arteaga Vallarta no.42, Tlalnepantla, Centro, Estado de Mexico, Mexico, Centro Oftalmologico Tlalnepantla, Dr. Perez-Arteaga Vallarta no.42, Tlalnepantla, Centro, Estado de Mexico, Mexico, Centro Oftalmologico Tlelnepantla, Tlelnepantla, Centro, Estado de Mexico, Centro Oftalmologico Tlalnepantla, Dr Perez - Arteaga Vallarta no.42, Tlalnepantla, Centro, Estado de Mexico 54000, Mexico, Centro Oftalmologico Tlalnepantl
2. The Eye Institute of West Florida, 148, 12th Street SW, Largo, Florida, USA, USA, 148 13th Street SW, Largo, The Eye Institute of West Florida, 148, 13th Street, SW, Largo Florida-33770, USA, The Eye Institute of West Florida, 148, 12th Street SW, Largo, Florida 33770, USA, Cataract and Refractive Surgeon, The Eye Institute of West Florida, 148, 12th Street SW, Largo, Florida 33770, USA
3. Clinique de I’ oeil, 15, Avenue du Bois-de-la-Chapelle, CH-1213 Onex, Switzerland, FMH Clinique de I’oeil, 15, Avenue du Bois-de-la-Chapelle, CH-1213 Onex, Switzerland, Clinique de I’oeil, 15, Avenue du Bois-de-la-Chapelle, CH-1213 Onex, Switzerland, Clinique de I’oeil, 15, Avenue du Bois-de-la-Chapelle, CH-1213 Onex (Switzerland), FMH, Clinique de L’oeil, 15, Avenyue Du Bois-de-law, CH-1213, Onex, Switzerland, FMH, Clinique de I’oeil , 15, Avenue du Bois-de-la-Chapelle, CH-1213 Onex, Switzerland, Clinique de L’oeil, 15, Avenyue Du Bois-de-law- Chapelle, CH-1213, Onex, Switzerland, FMH, Clinique de I’oeil, 15, Avenue du Bois-de-la-Chapelle, CH-1213 Onex, Switzerland, Clinique de I’oeil, 15, Avenue du Bois-de-la-Chapelle, CH-1213 Onex, 15, avenue du Bois-de-la Chapelle, CH-1213 Onex Geneva, Switzerland, Clinique de l’oeil, Avenue du bois de la chapelle, 1213 Onex Geneva, Switzerland, FMH, Clinique de L’oeil 15, Avenyue Du Bois-de-law, CH-1213, Onex, Switzerland
Chapter keywords
Increase the fluid, Phacodynamics, 0.9 mm incision, Bimanual 20G, Bimanual 19G, Fluidics dynamics, Aspiration, Irrigation, Passive infusion, Gravity force, Surge, Flow in, Flow out, Micro-bimanual, Peristaltic pump, Venturi pump, Sleeveless phaco, Switch instrumentation between hands, Polished tip, Cortical clean-up, Third incision.

Abstract

Related Books

© 2019 Jaypee Brothers Medical Publishers (P) LTD.   |   All Rights Reserved