Influence of CVD Diamond Tips and Er:YAG Laser Irradiation on Bonding of Different Adhesive Systems to Dentin

JOURNAL TITLE: The Journal of Contemporary Dental Practice

Author
1. Rebeca Di Nicolo
2. Daphne Câmara Barcellos
3. Alessandra Buhler Borges
4. Cesar Rogério Pucci
5. Melissa Aline da Silva
6. Carlos Rocha Gomes Torres
7. Graziela Ribeiro Batista
ISSN
DOI
10.5005/jp-journals-10024-1262
Volume
14
Issue
1
Publishing Year
2013
Pages
7
Author Affiliations
    1. São José dos Campos School of Dentistry, São Paulo State University, São Paulo, Brazil
    1. Department of Restorative Dentistry, São José dos Campos School of Dentistry, São Paulo State University, São Paulo, Brazil
    1. Department of Restorative Dentistry, São José dos Campos School of Dentistry, São Paulo State University, São Paulo, Brazil
    1. Department of Restorative Dentistry, São José dos Campos School of Dentistry, São Paulo State University, São Paulo, Brazil
    1. Department of Restorative Dentistry, São José dos Campos School of Dentistry, São Paulo State University, São Paulo, Brazil
    1. Department of Restorative Dentistry, São José dos Campos School of Dentistry, São Paulo State University, São Paulo, Brazil
    1. Department of Social Dentistry and Children's Clinic, UNESP-São Paulo State University, São Jose dos Campos School of Dentistry, São Paulo, Brazil
  • Article keywords

    Abstract

    Aim

    The aim of this study was to compare the microtensile bond strength of three adhesive systems, using different methods of dentin preparation.

    Materials and methods

    A hundred and eight bovine teeth were used. The dentin from buccal face was exposed and prepared with three different methods, divided in 3 groups: Group 1 (DT)- diamond tip on a high-speed handpiece; Group 2 (CVD)-CVD tip on a ultrasonic handpiece; Group 3 (LA)-Er: YAG laser. The teeth were divided into 3 subgroups, according adhesive systems used: Subgroup 1-Adper Single Bond Plus/3M ESPE (SB) total-etch adhesive; Subgroup 2-Adper Scotchbond SE/3M ESPE (AS) selfetching adhesive; Subgroup 3-Clearfil SE Bond/Kuraray (CS) selfetching adhesive. Blocks of composite (Filtek Z250–3M ESPE) 4 mm high were built up and specimens were stored in deionized water for 24 hours at 37°C. Serial mesiodistal and buccolingual cuts were made and stick-like specimens were obtained, with transversal section of 1.0 mm2. The samples were submitted to microtensile test at 1 mm/min and load of 10 kg in a universal testing machine. Data (MPa) were subjected to ANOVA and Tukey's tests (p < 0.05).

    Results and conclusion

    Surface treatment with Diamond or CVD tips associated with Clearfil SE Bond adhesive produced significantly lower bond strength values compared to other groups. Surface treatment with Er: YAG laser associated with Single Bond Plus or Clearfil SE Bond adhesives and surface treatment with CVD tip associated with Adper Scotchbond SE adhesive produced significantly lower bond strength values compared to surface treatment with diamond or CVD tips associated with Single Bond Plus or Adper Scotchbond SE adhesives.

    Clinical significance

    Interactions between laser and the CVD tip technologies and the different adhesive systems can produce a satisfactory bonding strength result, so that these associations may be beneficial and enhance the clinical outcomes.

    How to cite this article

    Silva MA, Di Nicolo R, Barcellos DC, Batista GR, Pucci CR, Torres CRG, Borges AB. Influence of CVD Diamond Tips and Er:YAG Laser Irradiation on Bonding of Different Adhesive Systems to Dentin. J Contemp Dent Pract 2013;14(1):14-20.

    © 2019 Jaypee Brothers Medical Publishers (P) LTD.   |   All Rights Reserved